Level Controllers
Technical specifications
Technical Specifications - Models EPR 00,02
Materials:
- Body: thermoplastic
- Membrane: elastomer
- Terminals: brass
Fixation:
According to the model
Activation and return pressure:
- Adjustment range (activation pressure): 50 to 510 mmH2O
- Minimum back pressure: 20 mmH2O Activation and return tolerance: (on request)
Electric scheme:
Maximum current (220Vac - resistive load):
Current | Tensão | Contact us |
10(4)A | 250 Vac | NA |
A 4 | 250 Vac | NF |
A 1 | 250 Vac | NA and NF |
100 mA | 5 Vdc, 12 Vdc or 24 Vdc | NA and NF |
Useful life:
> 25.000 operations
Dielectric strength:
1.500 Vac - 1 min.
Terminal Type:
Faston 6,3 mm
Technical Specifications - EPR models 04, 05, 06, 07, 08 and 09
Materials:
- Body: thermoplastic
- Terminals: brass
- Support: plastic and metallic
Fixation:
- According to the model
Activation and return pressure:
- Adjustment range (activation pressure): 50 to 510 mmH2O
- Minimum back pressure: 20mmH2O
- Activation and return pressure tolerance: (on request)
Electric scheme:
Capacity of contacts:
DGERT | SPECIFICATION |
UL |
12A, 125Vac (resistive) 10A, 250Vac (resistive) 1/2HP, 125/250Vac
1A, 250Vac (resistive)* 3/4HP, 125/250Vac 0,1A, 24Vdc (resistive) |
SEMKO |
NO: 10(4)A, 250Vac NC: 4A, 250Vac 1A, 250Vac
0,1A, 5Vdc, 12Vdc, 24Vdc** |
*anti-spill contacts
**low current application
Useful life:
>25.000 operations for SEMKO certification;
> 6.000 operations for UL certification.
Terminal Type:
Faston 6,3mm
Support Models
01 A - Metallic support
01 B - Metal support
01 C - Metal support
03 A | 03 B - Metal support
04 - Metal support
05 - Metal support
06 - Metal support
07 - Metal support
08 A | 08 B - Plastic support
10 - Metal support
12 - Plastic support
Plastic support - 15
11 - Metal support
16 - Plastic support
Checklist for samples and quotations
To ensure preparation of samples and quotations suitable for your application, please provide the information below:
- Level Controller:
- fixed or adjustable
- mechanical fixation (choose the model that suits you)
- Load:
- resistive: voltage and current
- inductive: voltage, current and power factor
- Contact electrical diagram: Normally Closed, Normally Open or Inverter
- Level Controllers (mod. EPR 00, 02, 04, 05, 07, 08 and 09):
- actuation pressure (mmH2O)
- actuation pressure tolerance (mmH2O)
- back pressure (mmH2O)
- back pressure tolerance (mmH2O)
- Adjustable Level Controller (mod. EPR 06):
*Maximum pressure: operating pressure (mmH2O)
actuation pressure tolerance (mmH2O) back pressure (mmH2O)
back pressure tolerance (mmH2O)
*Minimum pressure: actuation pressure
actuation pressure tolerance (mmH2O) back pressure (mmH2O)
back pressure tolerance (mmH2O)
- Application:
- equipment on which it will be applied
- mounting positioning (vertical / horizontal)
* for the adjustable level controller (mod. EPR 06)
** provide the panel layout
** preferably provide the knob
- Estimated monthly consumption
- Quantity and delivery date of samples or estimated production start date
Note: Whenever possible, provide the equipment in which it will be applied and the special test conditions that are necessary.
Didn't find what you need?
Contact us using the form below, we can develop your product!