Water Inlet Valves
Technical specifications
MATERIALS
- Body: thermoplastic (PP, POM or PA+FV)
- Filter (single or double): plastic (removable), metallic (removable or not)
- Metal parts: galvanized steel
- Membrane: rubber (EPDM or Nitrile) silicone (non-toxic)
- Terminals: brass
- Recordings: according to customer specifications
OPERATING PRESSURE
- From 0,2 to 8 kgf/cm2 (rubber membrane);
- From 0,2 to 4 kgf/cm2 (silicone membrane - non-toxic); From 0,2 to 10 kgf/cm2 (maximum pressure, on request); At 0,2 kgf/cm2, minimum flow (without regulator) = 4 l/min; At 8 kgf/cm2, maximum flow (without regulator) = 30 l/min; Optional - flow regulators (5l/min., 6,5l/min.,
- 8 l/min., 12 l/min., 20 l/min. and other flow rates on request) OBS. flow measured directly in 3/4" tubing
Liquid temperature: 60°C
Above 60°C, upon request
Dielectric strength: 1.500Vac - 1 min.
Water outlet (hose connection):
Geometric layout in relation to the input:
- reta
- 90o
Number of inputs / outputs:
- 1 input / 1 output
- 1 input / 2 outputs
- 1 input / 3 outputs
Useful life:
> 50.000 operations
Terminal type (power):
- Straight pattern; folded (upon request); Faston 6,3 x 0,8 mm
- Faston 4,8 x 0,8 mm
- Case 2,5
COIL
- Flammability Options: V0 or HB
- Tension: 110/120 Vac / 60 Hz
220/240Vac / 50-60Hz
12Vdc
24Vdc
Other voltages on request.
Water inlet: Screw thread
- 3/4" x 11,5 - NHT
- .3/4" x 14 - NBR-8133
- 8,5mm Hose Spike (EVA 08 and EVA17)
- 1/2"X 14 - NBR -8133 (EVA 18)
- 1/2" X 14 - NPT (EVA 18), on request
OUTPUT DIMENSIONS (mm)
Custom code | B | C | Models |
01 | 13.5 | 14.5 | EVA 06, EVA 07 |
06 | 10.5 | 12.5 | EVA 07 |
07 | 10.5 | 12.0 | EVA 06, EVA 09, EVA 14 |
08 | 10.5 | -- | EVA 10, EVA 11 |
09 | 6.5 | -- | EVA 08 |
10 | 3/8" thread | 19 FPP | EVA 09, EVA 07 |
11 | 10.2 | -- | EVA 12, EVA 15 |
12 | 1/2" thread | 14 FPP | EVA 18 |
13 | 8 | -- | EVA 17 |
Support Models
Checklist for samples and quotations
To ensure preparation of samples and quotations suitable for your application, please provide the information below:
1. Water inlet valve model:
- dimensions/geometry
- output position in relation to input: straight or 90
- number of inputs / outputs: 1 input and 1 output, 1 input and 2 outputs or 1 input and 3 outputs
- Filter type: single or double, removable or not
2. Coil voltage: 110/120Vac / 60Hz, 220/240Vac / 50-60Hz, 12Vdc or 24Vdc
3. Position of the water inlet in relation to the support: A
4. Position of the coil in relation to the water inlet: upon request
5. Water inlet thread: 3/4" x 11,5FPP - NHT or 3/4" x 14FPP - NBR - 8133 or 3/8" x 19FPP or ½"x 14FPP -NBR - 8133 or ½"x14PP ( NPT)
6. Normal or non-toxic version (EPDM, Nitrilica or Silicone)
7. Filter:
- plastic - removable
- Metal - removable or not
8. Type of support: see Technical Specifications
9. Dimensions of the water outlet: see Technical Specifications
10. Mounting position of the bracket in relation to the coil (upon request)
11. Flow regulator:
- 5 l / min.
- 6,5 l / min.
- 8 l / min.
- 12 l / min.
- 20 l / min.
- Other flows on request
- Without regulator (standard 30 l/min. at 8kgf/cm)
12. Application:
- working pressure range (kgf/cm) and flow (l/min.)
- equipment on which it will be applied
- liquid: specify the maximum temperature and if not clean water. E.g.: water with debris, chemicals, etc.
- service life: in test cycles and conditions
- temperature range to which it is exposed
- specific operating conditions
- test specifications
13. Estimated monthly consumption
14. Quantity and delivery date of samples or estimated production start date
Didn't find what you need?