Voltage Transformers

EUS 03- Voltage Transformer


Coding of available options

EUS 05 - Voltage transformer - quick assembly


Coding of available options

EUS 06 - Voltage transformer - 1 or 2 outputs


Coding of available options

EUS 09 - Voltage Transformer - 1 to 6 outputs


Coding of available options

EUS 09 - Voltage transformer with gas tube fixation - 1 to 8 outputs


Coding of available options

Technical specifications

Materials:

  • Body: thermoplastic
  • Encapsulation: resin
  • Terminals: nickel plated/tinned steel

Maximum operating temperature: 120oC

Output voltage:

  • EUS 03,05 and 09: 21.500V
  • EUS 06: 13.000V

Food:

Tension:

  • 110/120 Vac - 60Hz
  • 220/240 Vac - 60Hz
  • 220/240 Vac - 50Hz

Average consumption:

  • EUS 03,05 and 09: 10Hz at 110/120Vac - 20mA, at 220/240Vac - 40mA
  • EUS 06: 8Hz at 110/120Vac - 6mA, at 220/240Vac - 13mA

Maximum distance from the spark:

4 mm

Terminals:

  • Food: Faston 6,3 mm
  • Output: Faston 6,3 or 2,8 mm, other dimensions on request

Useful life:

  • > 100.000 cycles (EUS 03,05 and 09)
  • > 25.000 cycles (EUS 06)

Dielectric strength:

1.500Vac - 1 min.

Number of departures:

  • EUS 03,05 and 09: 1 to 8 departures
  • EUS 06: 1 or 2 departures

Technology:

Electronics

 

Support Models

01 A - Metallic support

01 B - Metal support

01 C - Metal support

03 A | 03 B - Metal support

04 - Metal support

05 - Metal support

06 - Metal support

07 - Metal support

08 A | 08 B - Plastic support

10 - Metal support

12 - Plastic support

Plastic support - 15

11 - Metal support

16 - Plastic support

Checklist for samples and quotations

To ensure preparation of samples and quotations suitable for your application, please provide the information below:

  1. Level Controller:
    • fixed or adjustable
    • mechanical fixation (choose the model that suits you)
  2. Load:
    • resistive: voltage and current
    • inductive: voltage, current and power factor
  3. Contact electrical diagram: Normally Closed, Normally Open or Inverter
  4. Level Controllers (mod. EPR 00, 02, 04, 05, 07, 08 and 09):
    • actuation pressure (mmH2O)
    • actuation pressure tolerance (mmH2O)
    • back pressure (mmH2O)
    • back pressure tolerance (mmH2O)
  5. Adjustable Level Controller (mod. EPR 06):

*Maximum pressure: operating pressure (mmH2O)
actuation pressure tolerance (mmH2O) back pressure (mmH2O)
back pressure tolerance (mmH2O)

*Minimum pressure: actuation pressure
actuation pressure tolerance (mmH2O) back pressure (mmH2O)
back pressure tolerance (mmH2O)

  1. Application:
    • equipment on which it will be applied
    • mounting positioning (vertical / horizontal)

* for the adjustable level controller (mod. EPR 06)
** provide the panel layout
** preferably provide the knob

  1. Estimated monthly consumption
  2. Quantity and delivery date of samples or estimated production start date

Note: Whenever possible, provide the equipment in which it will be applied and the special test conditions that are necessary.