My account
Access the restricted area

Find a distributor

Home 9 Laundry 9 Water Inlet Valves

Water Inlet Valves

EVA 06: Simple Straight Water Inlet Valve


Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 07: Single 90° Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 08: Simple Straight Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 09: Double Straight Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 10: Simple Straight Water Inlet Valve with Plastic Bracket

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 11: Double Straight Water Inlet Valve with Plastic Support

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 12: 90° Outlet Water Inlet Triple Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 14: Dual 90° Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 15: Dual 90° Outlet Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 16: Triple Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 17: Simple Straight Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 18: Single 90° Water Inlet Valve Threaded Outlet

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 22: Triple Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 23: Triple Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 24: Triple Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 25: Double Straight Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 27: Triple Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 28: Dual 90° Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 30.A: High Flow Double Inlet Water Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 30.B: High Flow Double Inlet Water Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

EVA 32: Triple Water Inlet Valve

Coding of available options (Single Valve)
(see checklist for samples and quotations)

Technical specifications

MATERIALS

  • Body: thermoplastic (PP, POM or PA+FV)
  • Filter (single or double): plastic (removable), metallic (removable or not)
  • Metal parts: galvanized steel
  • Membrane: rubber (EPDM or Nitrile) silicone (non-toxic)
  • Terminals: brass
  • Recordings: according to customer specifications

OPERATING PRESSURE

  • From 0,2 to 8 kgf/cm2 (rubber membrane);
  • From 0,2 to 4 kgf/cm2 (silicone membrane - non-toxic); From 0,2 to 10 kgf/cm2 (maximum pressure, on request); At 0,2 kgf/cm2, minimum flow (without regulator) = 4 l/min; At 8 kgf/cm2, maximum flow (without regulator) = 30 l/min; Optional - flow regulators (5l/min., 6,5l/min.,
  • 8 l/min., 12 l/min., 20 l/min. and other flow rates on request) OBS. flow measured directly in 3/4" tubing

Liquid temperature: 60°C

Above 60°C, upon request

Dielectric strength: 1.500Vac - 1 min.

Water outlet (hose connection):

Geometric layout in relation to the input:

  • reta
  • 90o

Number of inputs / outputs:

  • 1 input / 1 output
  • 1 input / 2 outputs
  • 1 input / 3 outputs

Useful life:

> 50.000 operations

Terminal type (power):

  • Straight pattern; folded (upon request); Faston 6,3 x 0,8 mm
  • Faston 4,8 x 0,8 mm
  • Case 2,5

COIL

  • Flammability Options: V0 or HB
  • Tension: 110/120 Vac / 60 Hz
    220/240Vac / 50-60Hz
    12Vdc
    24Vdc

Other voltages on request.

Water inlet: Screw thread

  1. 3/4" x 11,5 - NHT
  2. .3/4" x 14 - NBR-8133
  3. 8,5mm Hose Spike (EVA 08 and EVA17)
  4. 1/2"X 14 - NBR -8133 (EVA 18)
  5. 1/2" X 14 - NPT (EVA 18), on request

OUTPUT DIMENSIONS (mm)

Custom code B C Models
01 13.5 14.5 EVA 06, EVA 07
06 10.5 12.5 EVA 07
07 10.5 12.0 EVA 06, EVA 09, EVA 14
08 10.5 -- EVA 10, EVA 11
09 6.5 -- EVA 08
10 3/8" thread 19 FPP EVA 09, EVA 07
11 10.2 -- EVA 12, EVA 15
12 1/2" thread 14 FPP EVA 18
13 8 -- EVA 17

Support Models

Checklist for samples and quotations

To ensure preparation of samples and quotations suitable for your application, please provide the information below:

1. Water inlet valve model:

  • dimensions/geometry
  • output position in relation to input: straight or 90
  • number of inputs / outputs: 1 input and 1 output, 1 input and 2 outputs or 1 input and 3 outputs
  • Filter type: single or double, removable or not

2. Coil voltage: 110/120Vac / 60Hz, 220/240Vac / 50-60Hz, 12Vdc or 24Vdc

3. Position of the water inlet in relation to the support: A

4. Position of the coil in relation to the water inlet: upon request

5. Water inlet thread: 3/4" x 11,5FPP - NHT or 3/4" x 14FPP - NBR - 8133 or 3/8" x 19FPP or ½"x 14FPP -NBR - 8133 or ½"x14PP ( NPT)

6. Normal or non-toxic version (EPDM, Nitrilica or Silicone)

7. Filter:

  • plastic - removable
  • Metal - removable or not

8. Type of support: see Technical Specifications

9. Dimensions of the water outlet: see Technical Specifications

10. Mounting position of the bracket in relation to the coil (upon request)

11. Flow regulator:

  • 5 l / min.
  • 6,5 l / min.
  • 8 l / min.
  • 12 l / min.
  • 20 l / min.
  • Other flows on request
  • Without regulator (standard 30 l/min. at 8kgf/cm)

12. Application:

  • working pressure range (kgf/cm) and flow (l/min.)
  • equipment on which it will be applied
  • liquid: specify the maximum temperature and if not clean water. E.g.: water with debris, chemicals, etc.
  • service life: in test cycles and conditions
  • temperature range to which it is exposed
  • specific operating conditions
  • test specifications

13. Estimated monthly consumption

14. Quantity and delivery date of samples or estimated production start date

Didn't find what you need?

Contact us using the form below, we can develop your product!